5.2.6. Checks of components of systems of heating and To/in
Broad valve
PERFORMANCE ORDER |
|
|
Pressure switch
Main relay of a heater
PERFORMANCE ORDER |
|||
|
Relay of the magnetic coupling
PERFORMANCE ORDER |
|||
|
Condenser fan
PERFORMANCE ORDER |
|||
|
Checks of system through ECU contacts
The table of tension on contacts of the control unit of the K/V serviceable system under certain conditions is given below.
Contacts of the module of management To/in
Contacts |
Color of wires |
Check conditions |
Tension, In |
<—>IG GND <—>(C14-1 S14-11) |
<—>R-L BR |
Ignition is included |
10 ÷ 14 |
IN <—>GND <—>(C14-3 C14-11) |
<—>W-L BR |
Constantly |
10 ÷ 14 |
<—>BLW GND <—>(C14-4 C14-11) |
<—>P-L BR |
Ignition is included. The fan switch in the provision of "ON" |
1 ÷ 3 |
THERE <—>SG-5 <—>(C14-7 C14-16) |
<—>BR WR |
External temperature 25th hail. |
1.35 ÷ 1.75 |
External temperature 40th hail. |
0.85 ÷ 1.25 |
||
<—>TR SG-3 <—>(C13-3 S13-9) |
GR <—>of G-W |
Temperature of salon 25 hail. |
1.8 ÷ 2.2 |
Temperature of salon 40 hail. |
1.2 ÷ 1.6 |
||
<—>TPI SG-2 <—>(C13-11 C13-1) |
<—>GR B-W |
The REC switch is pressed |
3.5 ÷ 4.5 |
The FRS switch is pressed |
0.5 ÷ 1.5 |
||
<—>AIR GND <—>(C13-12 C14-11) |
<—>R BR |
The FRS switch is pressed |
10 ÷ 14 |
The REC switch is pressed |
Lower than 1.0 |
||
<—>A I F GND <—>(C13-13 C14-11) |
<—>BR-W BR |
The FRS switch is pressed |
Lower than 1.0 |
The REC switch is pressed |
10 ÷ 14 |
||
<—>TS S5-3 <—>(C13-15 C13-16) |
<—>Y-B L |
The sensor is lit with an electric lamp |
0.8 ÷ 4.3 |
The sensor is spread with rags |
Lower than 0.8 |
||
THOSE <—>SG-1 <—>(C12-1 C12-9) |
<—>G-Y B-Y |
Evaporator 0 temperature hail. |
2.0 ÷ 2.4 |
Evaporator 15 temperature hail. |
1.4 ÷ 1.8 |
||
<—>TPO SG-1 <—>(C12-3 S12-9) |
<—>LG-R B-Y |
Ignition is included. The FACE mode is chosen |
3.5 ÷ 4.5 |
Ignition is included. The forward DEF switch is pressed |
0.5 ÷ 1.5 |
||
<—>AOD GND <—>(C12-4 C14-11) |
<—>LG-B BR |
Ignition is included. The FACE mode is chosen |
Lower than 1.0 |
Ignition is included. The DEF mode is chosen |
10 ÷ 14 |
||
<—>AOF GND <—>(C12-5 C14-11) |
<—>W BR |
Ignition is included. The FACE mode is chosen |
10 ÷ 14 |
Ignition is included. The DEF mode is chosen |
Lower than 1.0 |
||
<—>TP SG-1 <—>(C12-6 C12-9) |
<—>O B-Y |
Ignition is included. Temperature regulator in the provision of the maximum cooling |
3.5 ÷ 4.5 |
Ignition is included. Temperature regulator in the provision of the maximum warming up |
0.5 ÷ 1.5 |
||
AMH <—>GND <—>(C12-7 S14-11) |
<—>Y-G BR |
Ignition is included. Temperature regulator in the provision of the maximum warming up |
10 ÷ 14 |
Ignition is included. Temperature regulator in the provision of the maximum cooling |
Lower than 1.0 |
||
<—>AMC GND <—>(C12-8 S14-11) |
<—>Y BR |
Ignition is included. Temperature regulator in the provision of the maximum cooling |
10 ÷ 14 |
Ignition is included. Temperature regulator in the provision of the maximum warming up |
Lower than 1.0 |