6. A power supply system and production of the fulfilled gases
Specifications
Power supply system type | The direct injection (distributed, consecutive), under control of ECM |
The supported pressure in a power supply system, atm | 3.0 ÷ 3.4 |
Pressure in a power supply system in 5 minutes after switching off of the engine, atm | not less than 1.45 |
Resistance of injectors, Ohm | 13.4 ÷ 14.2 |
Resistance between contacts 4 and 5 разъ÷ма the fuel pump, Ohms | 0.2 ÷ 0.3 |
The fuel volume injected by an injector for 15 with, cm 3 | 60 ÷ 73 |
Difference of the volumes of fuel injected by different injectors for 15 pages, cm 3 | no more than 13 |
Resistance of the MAF sensor (Ohm) at a temperature: | |
|
14.6 ÷ 17.8 |
|
2.21 ÷ 2.69 |
|
0.49 ÷ 0.67 |
Resistance of the TPS sensor, kOhm | |
|
0.2 ÷ 6.3 |
|
2.0 ÷ 10.2 |
|
2.5 ÷ 5.9 |
Resistance of the ECT sensor (kOhm) at a temperature: | |
|
10 ÷ 20 |
|
4 ÷ 7 |
|
2 ÷ 3 |
|
0.9 ÷ 1.3 |
|
0.4 ÷ 0.7 |
|
0.2 ÷ 0.4 |
Gap between adjusting screws of a butterfly valve and its lever at the closed gate, mm | |
|
0.13 |
|
0.22 |
Gap between the adjusting screw of a butterfly valve on the party of closing and its lever at the open gate, mm | 0.25 ÷ 0.45 |
Resistance between contact + B and other contacts of the IAC valve, Ohm | |
|
17.0 ÷ 24.5 |
|
21.5 ÷ 28.5 |
Resistance of the VVT-i valve, Ohm | 6.9 ÷ 7.9 |
Resistance of VSV No. 1 and No. 2 of the ACIS system, Ohm | 33 ÷ 39 |
Resistance of VSV of the EVAP system, Ohm | 27 ÷ 33 |
Resistance of the VSV sensor of pressure of fuel evaporations, Ohm | 33 ÷ 39 |
Resistance of VSV is CCV, Ohm | |
|
25 ÷ 30 |
|
33 ÷ 42 |
Resistance of the VSV valve of a purge of an adsorber, Ohm | |
|
37 ÷ 44 |
|
51 ÷ 62 |
Supply voltage of the sensor of pressure of fuel evaporations, In | 4.5 ÷ 5.5 |
The output tension of the sensor of fuel evaporations, In | |
|
1.3 ÷ 2.1 |
|
3.0 ÷ 3.6 |
|
4.2 ÷ 4.8 |
Resistance of heaters of A/F sensors and lambda probe, Ohm | 11 ÷ 16 |
Residual pressure in the line of a purge of an adsorber (in not less than 2 min. after giving of pressure of 25.2 ÷ 29 mm of mercury.) at the pressed hose of dumping of air, mm Hg. | 14:39 ÷ 16.45 |
Residual vacuum in the line of a purge of an adsorber (through not less than 5 pages) after giving of tension on contacts of VSV EVAP, mm. hg. | 9.35 ÷ 501 |
Content of harmful substances in OG
Temperature of motive oil at measurement of maintenance of CO in OG, a hail | 80 |
Volume fraction of maintenance of CO in OG at turns of H/H, % | no more than 0.5 |
Volume fraction of maintenance of CO in OG at turns 2400 ÷ 2600, % | 0.3 |
Volume fraction of maintenance of CO 2 in OG at turns of H/H, % | 14.5 ÷ 16 |
Volume fraction of contents O 2 in OG at turns of H/H, % | 0.1 ÷ 0.5 |
The maintenance of HC in OG at turns of H/H, particles on one million | 100 |
Coefficient of excess of air at an ideal (14.5:1) stoichiometric ratio | 0.98 ÷ 1.02 |
Efforts of tightening of threaded connections, Nanometer
Fixture of forward section of an exhaust pipe | |
|
62 |
|
48 |
Catalytic converter of a number of cylinders No. 1 | |
|
62 |
|
48 |
Bolts of fastening of assembly of the fuel pump to the fuel tank | 4 |
Bolts of fastening of the fuel filter | 2 |
Bolts of fastening of fuel distributive highways | 10 |
Bolt of fastening of a fuel tube to the inlet pipeline | 19.5 |
Bolts of fastening of bandage tapes of the fuel tank | 39 |
IAC valve fixture | 14.5 |
Connecting bolts of sections of the case of a throttle | 6.9 |
Nuts of fastening of the case of a throttle to the air distributor | 19.5 |
Bolt of fastening of a rack of the smoothing receiver | 19.5 |
Bolt of fastening of the VVT-i valve | 8 |
Nuts of fastening of an arm of the DLC socket No. 1 | 19.5 |
Fixture of the left back seat to a body | 37 |
ECT sensor | 20 |
Detonation sensor | 39 |
A/F sensors, lambda probe | 44 |